Search Site

CAN 16 InputCAN Module (P318)

P318The Trio CAN16 Input module offers a compact DIN rail mounted output expansion capability for all Trio Motion Coordinators. Up to 16 modules may be connected to the CAN network which may be up to 100m long.

This provides 256 distributed input channels at 24Vdc level. All input points are high level (24V in = ON) and completely isolated from the CANbus.

P318 modules may be mixed on the same bus, with other types in the Trio CAN I/O range. The Trio CANbus I/O expansion can considerably reduce machine wiring.

Inputs CAN link for up to 16 modules over 100m @ 500kHz
Configuration 16 input channels
Protection Outputs are overcurrent and over temperature rated
Indicators Individual status LED's
Address Setting Via DIP switches
Power Supply 24V / 1.5w
Mounting DIN rail mount
Size 26mm wide x 85mm deep x 130 mm high
  dimensions
Weight 168g
CAN 500kHz, Up to 256 expansion output channels
EMC EN61000-6-2 (2005) Industrial Noise Immunity/ EN61000-6-4 (2007) Industrial Noise Emissions.
CAN protocol Trio CANI/O or CANopen DS401
Data Sheet All CAN Modules
View Application Notes Technical notes
Quick Start Guide Simple set up guide (covers P316, P317, P318, P319, P326 and P327)

Package Drawings

 
Drawings are available in the following formats: DXF, IGES, DWG, STEP and SolidWorks.
These files are included in the Zip file below.
 
Download Zip file  

Manuals

The Technical Reference Manual can be downloaded in full or as separate sections. All in PDF format
I-O Expansion Modules (chapter 5)(1.6Mb)